This Machine is Used For Checking the Can’s For Leakage on Side Seam And End Seam.
The ‘Can’ to be Tested is Presented Between Two Plates, Open End of the Can Towards Rubberised Plate and Closed End Towards Metal Plate. Can is Held Firmly Between Plates.
To Dip the Can in the Water Tank a Hand Operated Lever of the Value to be Turned. Air is Forced into the Can Automatically in the Dipped Position Only. Pressure Regulator Provided to Regulate the Air Pressure.
Leakers Could be Detected by the Bubbles Emanating Through the Water.
Max dia of the clamp plates |
245mm |
Dia of Rubber pad |
240mm. |
Can closing range |
50mm |
Admit between clamp plates |
300mm Max |
Max working Pr. |
5kg/cm² |
Overall Dimension |
Base area |
W x L = 1500mm x 1000mm | |
Hight = 1700mm | |
Gross Weight |
200 Kgs |